Disconnect Sub-devices from EnOS™ Cloud


Upstream

  • Request TOPIC: /ext/session/{productKey}/{deviceKey}/combine/logout

  • Reply TOPIC: /ext/session/{productKey}/{deviceKey}/combine/logout_reply

Sample Request Format

{
  "id": 123,
  "params": {
    "productKey": "yourProductKey",
    "deviceKey": "yourDeviceKey"
  },
  "version":"1.0",
  "method":"combine.logout"
}

Sample Response Format

{
  "id": "123",
  "code": 200,
  "message": "",
  "data": {
  }
}

Request Parameter Description

Parameter

Type

Mandatory/Optional

Description

id

String

Optional

The message ID. It is a reserved parameter that is reserved for future use.

params

List

Mandatory

The parameters used for disconnecting sub-devices from EnOS Cloud.

deviceKey

String

Mandatory

The device key of the sub-device.

productKey

String

Mandatory

The product key of a sub-device.

method

String

Mandatory

The request method.

Response Parameter Description

Parameter

Type

Mandatory/Optional

Description

code

Integer

Mandatory

The return code. “200” indicates the request operation is executed successfully.

message

String

Optional

The response message.

data

JSON

Optional