Configuring Landing Page¶
The page describes how to configure a Landing Page in Unified Monitoring.
Prerequisites¶
Before configuring a Landing Page, make sure that:
You have the required permissions for assets, operations, and menu groups. Contact the application administrator to acquire the required permissions.
You have registered the attributes, measurement points, and metrics of related assets in Common Data Service. For more information, see About EnOS Common Data Service.
You have published the configured DTV page and acquired the URL of the page. For more information, see Publishing Dashboard Pages.
If you need to synchronize widget templates from DTV to Unified Monitoring, You need to add tags for the templates to be synchronized. For more information, see Widget Template.
Managing Page URL¶
The default URL of a Landing Page is {domain-name}/encom-landing-page/?url=&landingpage={}
. After publishing a configured DTV page, integrate the page into the Landing Page module of Unified Monitoring by the following steps:
Replace the value of the
url
parameter with the URL of the DTV page. For example, if the URL of the DTV page is{domain-name}/dt/encompass/page/2fe2ca90-c60b-46ba-ba77
, you need to set the value of theurl
parameter as{domain-name}/dt/encompass/page/2fe2ca90-c60b-46ba-ba77
.Note
If the domain (
{domain-name}
) of Unified Monitoring is the same as the domain of DTV, you can omit the{domain-name}
part in the Landing Page URL.Configure other parameters in the Landing Page URL to enable or disable related functions. For more information about the URL parameters of Landing Page, see Landing Page Parameters.
Select OK.
After configuring the URL of the Landing Page, the published DTV page serves as the default page of Landing Page. Based on the default page, you can add, edit, or move widgets on the page to meet the needs of business scenarios.
Managing Widgets¶
You can add or edit the visualized DTV widgets in Landing Page. For more information about configuring visualized widgets, see Adding Widget.
Adding Widget Templates¶
Select Landing Page from the left navigation pane.
Note
The menu name in your applications might be different from the name in this article, because of the customization on menu names for Unified Monitoring pages. Contact the application administrator for more information.
Select the Add Widget button, select the widget template you want to add to the page from the popup window and select Add to Page.
Configuring Widget¶
Select Landing Page from the left navigation pane.
Hover over the ellipsis (…) of the widget you want to edit and select Edit to open the Widget Editor page.
In the Widget Editor page, you can edit widget information such as basic information, data fields, style settings, and filters. For more information about editing widgets in Widget Editor, see Widget.
(Optional) To save the configured widget for future use, select Save as Template, enter the project, name, and tag information in the popup window and select OK to save the configured widget as a template.
Select Update and select Save on Page Editor.
Resetting Page Configuration¶
If you want to undo all editing operations performed in the Landing Page module, reset the page configuration to the state when publishing the related DTV page by the following steps: